Guangdong Bell Experiment Equipment Co., Ltd

Contact Us: sales@belltestchamber.com +86 769 2328 0911

Manufacturer from China
Active Member
5 Years
Home / Products / Battery Test Chambers /

High and Low Temperature Alternation Temperature Humidity Climatic Test Chamber Environmental Chambers

Contact Now
Guangdong Bell Experiment Equipment Co., Ltd
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrChoi
Contact Now

High and Low Temperature Alternation Temperature Humidity Climatic Test Chamber Environmental Chambers

Ask Latest Price
Video Channel
Brand Name :DGBELL
Model Number :BTHW-15m
Certification :CE/ISO
Place of Origin :China
MOQ :1pcs
Price :Negotiation
Payment Terms :Western Union, T/T, D/P, D/A, L/C
Supply Ability :500 Sets per Month
Delivery Time :Negotiation
Packaging Details :Each set protected with resin fiber and PP film, then put into Strong wooden case with operation manual inside.
Keywords :Climatic Test Chamber for Battery
Inner Box Size :W3000×H2000×D2500 (mm)
External Dimensions :W4600×H2480×D2800(mm)
Humidity Range :20%RH~98%RH Low humidity requirement: minimum can reach 5%RH
Temperature Fluctuation :≤±0.5ºC
Temperature Deviation :≤±2.0ºC
Temperature Uniformity :≤±2.0ºC
Humidity Fluctuation :≤±2.5ºC
Humidity Deviation :Humidity>75%RH:≤+2,-3%RH;Humidity<75%RH:≤±5%RH
Temperature Rise Rate :≥3ºC/MIN
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

High and Low Temperature Alternation Temperature Humidity Climatic Test Chamber Environmental Chambers

Technical Parameters

Product Model

BTHW-15m³ (or 8m³, 10m³, 12m³, 30m³, 80m³)

Inner Box Size

W3000×H2000×D2500 (mm)

External Dimensions

W4600×H2480×D2800(mm)

Temperature Range

A type: 0 ºC ~ +120 ºC, B type: -20 ºC ~ +120 ºC, C type: -40 ºC ~ +10 ºC, D type: -60 ºC ~ +10 ºC (adjustable)

Humidity Range

20%RH~98%RH Low humidity requirement: minimum can reach 5%RH

Temperature Fluctuation

≤±0.5ºC

Temperature Deviation

≤±2.0ºC

Temperature Uniformity

≤±2.0ºC

Humidity Fluctuation

≤±2.5ºC

Humidity Deviation

Humidity>75%RH:≤+2,-3%RH;Humidity<75%RH:≤±5%RH

Temperature Rise Rate

≥3ºC/MIN

Cooling Rate

≥1ºC/MIN

Control System

PLC + touch screen control, network, with USB interface, with 485 interface can be connected to computer control, special network control software, convenient remote monitoring, data acquisition.

Cooling Method

Water-cooled

Wiring Hole

Diameter 100MM, quantity 2 sets or more

Other Requirements

Sub-carriage for easy access of products to equipment

Explosion-proof lighting system

Explosion-proof pressure relief system

Smoke exhaust system

Automatic water replenishment system

Fire extinguishing devices, sprinklers, smoke alarm devices, etc.

Inquiry Cart 0